{"product_id":"self-cleaning-magnetic-filter","title":"Self Cleaning Magnetic Filter","description":"\u003ch4\u003eProduct Description\u003c\/h4\u003e\n\u003cp\u003eThe Self Cleaning Filter series is the latest generation of self- purging high intensity magnetic filters for high flow, high contamination industrial applications.\u003c\/p\u003e\n\u003cp\u003eThe Self Cleaning Filter model will have 2 chambers, Fluid enters the inlet chamber where primary filtration takes place. The partly treated fluid flows into a second chamber where it is slowed so that the final filtration treatment can take place. It then returns to the process.\u003c\/p\u003e\n\u003cp\u003eInstalling Self Cleaning Filter will improve your manufacturing effectiveness and reduce operator intervention.\u003c\/p\u003e\n\u003ch4\u003eUsing fully filtered fluid, free from micron sized particles will:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eImprove surface finish\u003c\/li\u003e\n\u003cli\u003eImprove fluid flow\u003c\/li\u003e\n\u003cli\u003eCut costs on scrap reduction\u003c\/li\u003e\n\u003cli\u003eReduce downtime\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTypical Applications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eGrinding\u003c\/li\u003e\n\u003cli\u003eHoning\u003c\/li\u003e\n\u003cli\u003eMilling\u003c\/li\u003e\n\u003cli\u003eFine finishing\u003c\/li\u003e\n\u003cli\u003eLiquid Pharma products\u003c\/li\u003e\n\u003cli\u003eLiquid Chemicals\u003c\/li\u003e\n\u003cli\u003eLiquid Food products\u003c\/li\u003e\n\u003cli\u003eLubricants\u003c\/li\u003e\n\u003cli\u003eCoolants\u003c\/li\u003e\n\u003cli\u003eHydraulic oils\u003c\/li\u003e\n\u003cli\u003eSlurries\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSchematic Drawing for Self Cleaning Magnetic Filter\u003c\/h4\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0309\/7625\/files\/cleaning-process-drawing.png?v=1627301937\" alt=\"Self cleaning magnetic filter\"\u003e\u003c\/p\u003e\n\u003ch4\u003eStandard Self Cleaning Filter\u003c\/h4\u003e\n\u003cdiv class=\"tg\"\u003e\n\u003ctable style=\"width: 100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: center;\" colspan=\"6\"\u003eStandard Self Cleaning Filter\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center; width: 15%;\"\u003e\u003cstrong\u003eModel\u003cbr\u003eNo.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 15%;\"\u003e\u003cstrong\u003eA(mm)\u003cbr\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 15%;\"\u003e\u003cstrong\u003eB (mm)\u003cbr\u003eDiameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 15%;\"\u003e\u003cstrong\u003eC (mm)\u003cbr\u003eFlange CTC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 15%;\"\u003e\u003cstrong\u003eNo. of\u003cbr\u003eMagnetic Elements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 25%;\"\u003e\u003cstrong\u003eRecommended For\u003cbr\u003eFlow Rates*\u003cbr\u003eLiters\/ per min\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center; width: 10%;\"\u003eSCF1\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 12%;\"\u003e835\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 10%;\"\u003e200\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 12%;\"\u003e540\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 13%;\"\u003e6\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 23%;\"\u003e500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center; width: 10%;\"\u003eSCF2\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 12%;\"\u003e1200\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 10%;\"\u003e250\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 12%;\"\u003e640\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 13%;\"\u003e8\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 23%;\"\u003e1200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center; width: 10%;\"\u003eSCF3\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 12%;\"\u003e1200\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 10%;\"\u003e300\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 12%;\"\u003e740\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 13%;\"\u003e12\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 23%;\"\u003e2000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eCleaning Process\u003c\/h4\u003e\n\u003cp\u003eA signal from your control system activates the outlet valve (not included) so fluid is redirected to a purge tank or reclamation unit (available as an option), then the centrally positioned pneumatic cylinder withdraws the magnetic elements from the filter\u003c\/p\u003e\n\u003cp\u003eWhen the contamination has been purged the magnetic elements are reinserted and the outlet valve is returned to position, bringing the unit back online. The complete cleaning cycle takes 10-15 seconds depending on fluid type and filter location.\u003c\/p\u003e\n\u003ch4\u003eSelf - Cleaning Magnetic Filter Systems have the following features:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThe magnetic filters can be installed easily in the fluid flow line\u003c\/li\u003e\n\u003cli\u003eThey give complete magnetic protection by attracting iron particles as fine as 10 microns into the magnetic trap\u003c\/li\u003e\n\u003cli\u003eThe magnets are installed in polished condition for the higher life of the rods and ease of cleaning\u003c\/li\u003e\n\u003cli\u003eFor different flow rates, different sizes of magnetic filters are available\u003c\/li\u003e\n\u003cli\u003eHigh-Intensity Rare Earth Magnets or Low-Intensity St. Ferrite Magnets are used depending upon the user's requirement\u003c\/li\u003e\n\u003cli\u003eNormally these filters are designed to take up pressures 5kg\/ cm\u003csup\u003e2\u003c\/sup\u003e. They can be designed to withstand higher pressure\u003c\/li\u003e\n\u003cli\u003eMaximum operating temperature 80ᵒC. They can be designed to work at temperatures as high as 200°C\u003c\/li\u003e\n\u003cli\u003eSelf purging\u003c\/li\u003e\n\u003cli\u003eNo maintenance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSelf cleaning Type Permanent Magnetic filters are used for the separation of iron particles from liquid.\u003c\/p\u003e\n\u003cp\u003eThe Magnetic filter is supplied with the pneumatic cylinders, FRL Unit \u0026amp; Timer with Operating button for controlling the cleaning.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Features: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSelf cleaning, air operated, for remote installations, frequent cleaning, or fully automated system\u003c\/li\u003e\n\u003cli\u003eRemoves Micron size iron contamination\u003c\/li\u003e\n\u003cli\u003eWear resistant tube treatment and special wiper seals for abrasive products\u003c\/li\u003e\n\u003cli\u003eCustomized Filter designs available\u003c\/li\u003e\n\u003cli\u003eFDA approved Food grade gasket material\u003c\/li\u003e\n\u003cli\u003eFinish and welding treatments available for food and sanitary grade applications\u003c\/li\u003e\n\u003cli\u003eMatching companion Flanges for easy installation.\u003c\/li\u003e\n\u003cli\u003e304\/316 stainless steel construction\u003c\/li\u003e\n\u003cli\u003eThe air-actuated stripper seal assembly discharges collected tramp metal into a catch pan as the drawer opens.\u003c\/li\u003e\n\u003cli\u003eHigh-intensity Drawer Type Grill with Maximum operating temperature up to 350ᵒC also available with SMCO (Samarium Cobalt Magnet).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eWhy PML Self Cleaning Filters?\u003c\/h4\u003e\n\u003col\u003e\n\u003cli\u003e65 years of experience in design and development of Permanent Magnets and Magnetic Systems\u003c\/li\u003e\n\u003cli\u003eMagnet Filters are available in 11,000 Gauss for operating temperature up to 120°C and 9000 Gauss at an operating temperature of 250°C\u003c\/li\u003e\n\u003cli\u003eSuper high-intensity magnetic rod also available with gauss value 12,000 for maximum operating temperature up to 80ᵒC.\u003c\/li\u003e\n\u003cli\u003eCustomized design\u003c\/li\u003e\n\u003cli\u003eMagnetic Filters are hydraulically tested to check leakage at welding joints and sealing points.\u003c\/li\u003e\n\u003cli\u003ePML offers comprehensive Magnetic Filtration Systems using 2\/3 Magnetic filters in series to ensure output contamination to a minimum PPM level.\u003c\/li\u003e\n\u003cli\u003eServices such as magnetic calibration\/Audit are available\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"PML","offers":[{"title":"Default Title","offer_id":39631236890702,"sku":"","price":0.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0309\/7625\/products\/self-cleaning-filter-front-1000x1000.png?v=1642418083","url":"https:\/\/shop.pmlindia.com\/products\/self-cleaning-magnetic-filter","provider":"Permanent Magnets Ltd","version":"1.0","type":"link"}