{"product_id":"plate-type-magnetic-chute","title":"Plate Type Magnetic Chute","description":"\u003cp\u003ePlate Type Magnetic Chutes with plates are for trapping ferrous particles mixed with dry, granular or powdered materials. They are generally used where flowing material characteristics are sticky and non-free-flowing.These systems are easy to clean and maintain.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0309\/7625\/files\/Plate-type-magnetic-chute-front-view-small.jpg?v=1587973418\" alt=\"Plate Type Magnetic Chute Front View\"\u003e  \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0309\/7625\/files\/Plate-type-magnetic-chute-back-view-small.jpg?v=1587973418\" alt=\"Plate Type Magnetic Chute back View\"\u003e  \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0309\/7625\/files\/Plate-type-magnetic-chute-open-back-view-small.jpg?v=1587973418\" alt=\"Plate-type-magnetic-chute-open-back-view\"\u003e  \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0309\/7625\/files\/Plate-type-magnetic-chute-open-front-view-small.jpg?v=1587973418\" alt=\"Magetic chute rod fittingPlate-type-magnetic-chute-open-front-view\"\u003e\u003c\/p\u003e\n\u003ch4\u003eIndustries Using Magnetic Chutes:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003ePlastics\u003c\/li\u003e\n\u003cli\u003eFood\u003c\/li\u003e\n\u003cli\u003eSpices\u003c\/li\u003e\n\u003cli\u003eChemicals\u003c\/li\u003e\n\u003cli\u003eDyes \u0026amp; Powder Pigments\u003c\/li\u003e\n\u003cli\u003ePharmaceutical industry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eStandard PML Magnet Chutes:\u003c\/h4\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg style=\"display: block; margin-left: auto; margin-right: auto;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0309\/7625\/files\/Plate-type-magnetic-chute-drawing-image-small.jpg?v=1587973419\" alt=\"Plate Type Magnetic chute drawing\"\u003e\u003c\/div\u003e\n\u003cbr class=\"clearfix\"\u003e\n\u003ctable class=\"tg\" style=\"width: 100%;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"4\"\u003eHigh intensity Easy-Clean Plate housing Magnet Permissible Max. Operating Temp. 80˚ C\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cb\u003eModel\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cb\u003eInlet \u0026amp; outlet Dia.(mm)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cb\u003eTotal HT.(mm)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cb\u003eAttraction Distance\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eECPHM 1\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e150\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e300\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e4”\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eECPHM 2\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e200\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e300\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e4”\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eECPHM 3\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e250\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e400\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e4”\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eECPHM 4\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e300\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e400\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e4”\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eECPHM 5\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e350\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e400\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e4”\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr class=\"clearfix\"\u003e\n\u003cp\u003e(Peak flux density value 4,000 ± 500 Gauss, when measured on separation frame)\u003c\/p\u003e\n\u003ctable class=\"tg\" style=\"width: 100%;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"6\"\u003eDimensions of Inlet \u0026amp; Outlet Connecting Flanges\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cb\u003eModel\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cb\u003eFlange O.D.(mm)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cb\u003eHole Dia.(mm)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cb\u003eNo. Of Holes\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cb\u003eHole PCD(mm)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cb\u003eFlange THK.(mm)\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eECPHM 1\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e279.4\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e22.2\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e8\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e241.3\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eECPHM 2\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e342.9\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e22.2\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e8\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e298.4\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eECPHM 3\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e406.4\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e25.4\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e12\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e361.9\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eECPHM 4\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e482.6\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e25.4\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e12\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e431.8\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eECPHM 5\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e533.4\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e28.6\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e12\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e476.2\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eConstruction:\u003c\/h4\u003e\n\u003cp\u003eIn a Plate type Magnetic Chute, the magnets are placed on the doors. The central Magnet is fitted on the hinged door and can be swung out for manual cleaning of arrested iron particles after the batch is over or at a decided frequency of cleaning. The chutes are generally placed vertically on the discharge ducts. However if required it can also be placed horizontally between the material flow lines.\u003c\/p\u003e\n\u003ch4\u003eFeatures:\u003c\/h4\u003e\n\u003cp\u003eMagnetic Chutes have following features:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe Plate Type Magnetic Chutes can be installed easily in a flow line.\u003c\/li\u003e\n\u003cli\u003eThe Flux density of Plate type magnetic chute (4,500) gauss is also available for 80ᵒC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eHigh-intensity Bullet Rod Type Magnetic Chute with 9,000 gauss value and maximum operating temperature up to 350ᵒC also available with SMCO (Samarium Cobalt Magnet).\u003c\/span\u003eFor different flow rates, the magnetic chutes of different sizes are available.\u003c\/li\u003e\n\u003cli\u003eHigh-Intensity Rare Earth Magnets are used fitting best to the user’s requirement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eHow does it work?\u003c\/h4\u003e\n\u003cp\u003eThe plate type magnetic chute is placed in the flow path of the materials passing through the ducts, with the help of flanges. As the material flows through the chute, the iron contamination gets attracted to the magnetic surface and the non-magnetic material flows out of it without any disturbance.\u003c\/p\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0309\/7625\/files\/Plate-type-magnetic-chute-design-view-small.jpg?v=1587973418\" alt=\"Plate Type Magnetic chute working process drawing\"\u003e\u003c\/div\u003e\n\u003ch4\u003eInformation required for the design of magnetic chutes:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSize of the duct and the flange with which the chute has to be fixed\u003c\/li\u003e\n\u003cli\u003eType of material and size of the particle\u003c\/li\u003e\n\u003cli\u003eSize and concentration of contamination\u003c\/li\u003e\n\u003cli\u003eFlow rate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eWhy PML Magnetic Chute?\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e60 years of experience in design and development of Permanent Magnets and Magnetic Systems\u003c\/li\u003e\n\u003cli\u003eMagnet Chutes are available with high intensity of 5000 Gauss\u003c\/li\u003e\n\u003cli\u003eCustomized Design\u003c\/li\u003e\n\u003cli\u003eServices such as magnetic calibration\/Audit are available\u003c\/li\u003e\n\u003cli\u003eArrested iron particles can be easily removed manually\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSome of PML’s valued customers:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eKwality Feed\u003c\/li\u003e\n\u003cli\u003eAvanti Feeds\u003c\/li\u003e\n\u003cli\u003eNational Capsules limited(NCL)\u003c\/li\u003e\n\u003cli\u003eNG Feeds\u003c\/li\u003e\n\u003cli\u003eRajdeep Engineering Systems (Pune) Pvt Ltd.\u003c\/li\u003e\n\u003cli\u003eHuber Group\u003c\/li\u003e\n\u003cli\u003eMorava Group\u003c\/li\u003e\n\u003cli\u003eRida Plastics\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"PML","offers":[{"title":"Default Title","offer_id":32038751993934,"sku":"","price":0.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0309\/7625\/products\/Plate-type-magnetic-chute-front-view-small.jpg?v=1588076075","url":"https:\/\/shop.pmlindia.com\/products\/plate-type-magnetic-chute","provider":"Permanent Magnets Ltd","version":"1.0","type":"link"}